Contactum CPBR0616B 16A Single Pole RCBO Type B 30mA 6kA Contactum - 1

Contactum CCPBR0616AB 16A Single Pole RCBO Type B 30mA 6kA

£13.82 VAT excluded
£16.58 VAT incl.
  • Contactum CCPBR0616AB 16A Single Pole RCBO Type B 30mA 6kA
  • Amps:16A
  • kA Rating:6
  • Single Pole
  • Type:B
  • Terminal capacity:16mm
  • certification:BS EN 61009
  • Voltage:220-250V
  • Milliamp:30mA
  • Contactum devices are all built tested to international, national quality control
  • Window on the device indicates on (Red) and off (Green)
  • For Use with Defender Consumer units
In Stock Next day delivery available

  100% Secure Payment

Card payments are managed via PayPal. Discountelectrical.com does not see or store card details.

  Returns accepted within 30 days

If you have an issue with a product we will be happy to exchange it or refund you.

The Contactum CCPBR0616AB 16A Single Pole RCBO Type B 30mA 6kA is an electrical protection device designed to provide both overcurrent protection and residual current protection in a single unit. Here are the features and benefits of this product:

Features:

16A Rated Current: The RCBO is rated for a maximum current of 16A, making it suitable for protecting electrical circuits with lower current loads.

Single Pole: The RCBO is a single pole device, meaning it can protect a single phase of an electrical circuit.

Type B: The RCBO is classified as Type B, indicating that it provides protection against both AC and pulsating DC residual currents.

30mA Sensitivity: The RCBO has a sensitivity of 30mA, which means it will trip and disconnect the circuit if a residual current of 30mA or higher is detected.

6kA Breaking Capacity: The RCBO has a breaking capacity of 6kA, allowing it to handle high fault currents and safely interrupt the circuit in the event of a fault.

Benefits:

Combined Protection: The RCBO provides both overcurrent protection and residual current protection in a single unit, saving space and simplifying installation.

Enhanced Safety: The Type B classification ensures protection against various types of residual currents, including AC and pulsating DC, improving electrical safety.

Fault Detection: The 30mA sensitivity allows the RCBO to detect low-level residual currents, providing effective protection against electric shocks and reducing the risk of electrical accidents.

Reliable Performance: With a 6kA breaking capacity, the RCBO can handle high fault currents, ensuring the circuit is safely disconnected in the event of a fault.

Compatibility: The 16A rating makes the RCBO suitable for a range of applications, including domestic and commercial installations, where lower current loads are present.

CCPBR0616AB

Data sheet

Voltage
220-250V
Amps
16A
Milliamp
30mA
kA Rating
6
Pole
1
Type
B
Terminal capacity
16mm
Certification